Sacramento, CA · Licensed CA / NV / AZ / WA

Preserving AgingInfrastructure

Corrosion Integrity is a design-build corrosion engineering firm. We survey, design and install the cathodic protection that keeps pipelines, storage tanks and concrete infrastructure in service — and we run the non-destructive testing that proves it is fit for service.

Fig. 1 — ICCP cross-section Structure-to-soil potential −0.912 V
Impressed current Steel structure Anode ground bed Active corrosion cell Criterion −850 mV CSE

Fig. 2 — Storage tanks

Same principle, inside the tank.

On a water storage tank the electrolyte is the water itself. Titanium wire anodes hang from the roof on insulated suspension leads, current spreads through the column onto the shell and floor, and a permanent reference cell reports what the steel is actually seeing — without draining the tank to find out.

Fig. 2 — Water storage tank ICCP Structure-to-water potential −0.964 V
Impressed current Steel shell and floor Titanium wire anode Permanent reference cell Criterion −850 mV CSE

Fit for service

An asset is either fit for service, or it is on a clock. We tell you which.

Corrosion Integrity evaluates infrastructure to determine whether the asset is fit for service, what its remaining useful life is, and whether it can continue to operate safely. Every answer comes from measurement — soil resistivity, structure-to-soil potential, wall thickness, coating adhesion — not from inspection by eye.

0+
Years combined engineering experience
0+
Years in corrosion engineering & construction
0
NDT & coating test methods in-house
0
States licensed — CA · NV · AZ · WA

Sectors served

Water & wastewater Nuclear Oil & gas Petroleum refining & distribution Electric power generation Bridges & tunnels Pier & piling Offshore marine structures Aqueducts Agriculture Government agencies Private industry

Capabilities

Engineer it, assess it, build it — under one point of contact.

Design-build means the engineer who specifies the system is accountable for the crew that installs it. One contact owns the schedule, the budget and the deliverables.

Engineering services

Soil resistivity surveys, laboratory corrosivity analysis, cathodic protection and monitoring system design, plans and specifications.

  • Cathodic protection design — galvanic and impressed current
  • Above-grade storage tanks and clarifiers
  • Atmospheric corrosion assessment
  • Reinforced concrete corrosion control
  • Coatings and paints consulting and inspection
  • Internal corrosion — coupons, LPR and ER probes
  • Interference and stray current studies
  • Corrosion failure analysis
  • Material selection for corrosive environments

Condition assessment

A comprehensive engineering report on the reliability of your facility, built from direct inspection, indirect monitoring and NDT — customizable to your expectations.

  • Assessments that follow or exceed ASTM standards
  • Remaining useful life (RUL) of each asset
  • Repair-or-replace recommendations, prioritized
  • Facility Condition Index (FCI) benchmark
  • Renewal and replacement cost estimates
  • Strategic repair, replacement and modernization plan
  • Preventive maintenance and capital planning
  • Referenced to ACI, ASTM, API, ISO and AMPP (NACE)

Construction & project management

Multimillion-dollar design-build delivery across nuclear, oil & gas, municipal and private sector work. Turn-key, with a site visit before the estimate.

  • Anode ground beds — distributed and deep well
  • Storage tank cathodic protection installation
  • Integrity digs and pipeline excavation
  • Rectifier, RMU and test station installation
  • Hydrovac and key holing services
  • AC mitigation and grounding wells
  • Submersible anode sled installation
  • Tank wash-down, cleaning and disinfection

Inspection & NDT

Twelve ways to find metal loss before it finds you.

Our engineers and technicians run these methods in-house, each assigned to a project by forensic specialty. Select a method for what it detects and where we apply it.

Ultrasonic thickness

$0BEstimated annual damage

It is estimated that more than $30 billion in corrosion damage occurs in water and wastewater handling systems every year.

Pipelines, storage tanks and treatment plants carry most of it. Cathodic protection, correctly designed and actually monitored, is the cheapest line item on the ledger — and the one most often skipped.

Talk through your asset

The criterion

Minus 850 millivolts is the line.

Cathodic protection is judged against a number, not an opinion. Drag the potential and watch where the steel sits.

−0.950VCSE Protected

Pipe wall — indicative surface condition
nominal wall
Reference
Cu / CuSO4 (CSE)
Criterion
−850 mV, IR-free
Measured
Instant-off or coupon

Illustrative only — a real assessment needs an IR-free potential and wall thickness data.

PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size C

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size D

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size D-NZ

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

3M 82-A1 Splice Kit

Inline splice kit for unshielded, synthetic-insulated cable. UL Listed for direct burial and submerged use to 600 V and 90 °C.

PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size E

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

3M 82-A2 Splice Kit

Inline splice kit for mid-range conductors. UL Listed for direct burial and submerged use to 600 V and 90 °C.

Quoted
PlaceholderSplice kits & sealing

3M 82-A3 Splice Kit

Inline splice kit for large conductors. UL Listed for direct burial and submerged use to 600 V and 90 °C.

Quoted
PlaceholderSplice kits & sealing

3M 82-B1 Splice Kit

Tap and branch splice kit for weather-exposed and direct-burial joints, to 5 kV with a solder sleeve or compression connector.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size A

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size B

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
Off-Grid PV PolePower & control

Off-Grid PV Pole

Pole-mounted array, enclosure and storage — a complete power package for remote cathodic protection sites.

Quoted
Clevis AssemblyTank hardware

Clevis Assembly

Anode suspension hardware for tank installations — takes the mechanical load off the anode lead.

GrommetTank hardware

Grommet

Sealed cable penetration for tank roofs and hand holes.

Titanium MMO AnodeAnodes

Titanium MMO Anode

Mixed metal oxide on titanium. The workhorse impressed-current anode for potable water and wastewater storage tanks.

from$600.00
Mag Rod AnodeAnodes

Mag Rod Anode

Magnesium rod for galvanic systems — tank interiors, small structures and retrofit protection.

8" Hand Hole Cover AssemblyUncategorized

8" Hand Hole Cover Assembly

316 stainless steel access cover in the larger shell size, for multiple cable entries or where the smaller cover will not clear the terminations.

TASC / IRT Controller CardUncategorized

TASC / IRT Controller Card

Replacement controller card for TASC and IR-free rectifier units. Material price; installation is charged at the crew day rate.

$1,200.00Add to cart
PlaceholderUncategorized

9 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

17 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

20 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

32 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

48 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

60 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

No. 10 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 8 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 6 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 4 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 2 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 1 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 1/0 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 2/0 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 4/0 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

5-Terminal Test Station Head

Five-terminal head for potential and current measurement points, taking the leads from the pipe, the anode and the shunt onto separate terminals so a reading is repeatable.

PlaceholderUncategorized

G5C Flush-Mount Box

Traffic-rated flush box for a station in a roadway, a shoulder or anywhere a post would be hit. The box goes in at grade and the terminal board mounts inside it.

PlaceholderUncategorized

G5CT Lid

Replacement lid for the G5C box — the part that actually gets destroyed, by a grader blade or a snow plough, long before the box does.

PlaceholderUncategorized

5" × 5" Terminal Board

Phenolic terminal board for a flush box, drilled for shunts and terminal posts so that current can be read without breaking a connection.

PlaceholderUncategorized

No. 2 Bond Jumper — 18"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 2 Bond Jumper — 24"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 2 Bond Jumper — 18" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

No. 2 Bond Jumper — 24" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

No. 4 Bond Jumper — 18"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 4 Bond Jumper — 24"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 4 Bond Jumper — 18" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

No. 4 Bond Jumper — 24" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

CAA Cadweld Mold with Frame

Horizontal graphite mold and handle frame for cadwelding a lead to the pipe wall. One mold is good for a run of welds before the graphite erodes past a clean joint.

PlaceholderUncategorized

Royston Handy Cap

Mastic cap over the finished weld, keeping water off the bare steel and the connection. Priced singly; a box is $120.80.

PlaceholderUncategorized

Cadweld Charges

Welding charges by the package, sized to the mold and the conductor. Tell us the mold and the lead you are welding and we will price the right package.

Quoted
PlaceholderUncategorized

3M 90-B1 Splice Kit

Branch and tap splice kit for direct-burial and submerged joints — the kit for taking an anode lead onto a header cable without leaving a path to water.

PlaceholderUncategorized

Scotch 130C Linerless Rubber Tape

Self-fusing ethylene propylene rubber tape. Stretched and wrapped it fuses into one mass with no seam for water to track along, which is what makes it a splice tape rather than an insulating one.

PlaceholderUncategorized

Scotch Super 88 Vinyl Tape

Heavier vinyl tape for the same job where the splice will be pulled through soil or rock and the thinner jacket would abrade through.

PlaceholderUncategorized

C-Crimps and Split Bolts

Compression C-crimps and split-bolt connectors, sized to the conductors being joined. Tell us the two gauges and we will price the connector.

Quoted
PlaceholderUncategorized

Pin Brazing — Materials and Installation

Pin brazed lead attachment where a cadweld is not permitted — thin wall, high pressure, or an operator who will not allow an exothermic weld on a live line. Quoted with the materials and the technician together.

Quoted
0 items in quote

Safety & training

Our foundation is safety. Our people are certified to prove it.

We invest in employee development and in the reporting culture that keeps hazards visible before they become incidents.

Built on dedication to safety

Corrosion Integrity's success and foundation is built on our dedication to safety. Crews carry current certifications, and every project runs safety observation reporting and hazard identification.

NCCERVeriforceMEA ISNetworldOSHA Safety observation reportingHazard ID program

Classes & certifications

API RP 578 — Material Verification Program

API 578 gives guidelines for a Material Verification Program (MVP) to confirm the correct chemical composition of alloy materials in new and existing process piping systems across oil, gas and petrochemical service.

  • Purpose — establish a quality assurance system for material verification, preventing wrong material installation that leads to accelerated corrosion or component failure.
  • Scope — ferrous and nonferrous alloy materials in new and existing process piping systems and equipment.
Call (213) 336-5867 for availability

Coverage

Headquartered in Sacramento. Mobilized across the West.

Two offices, four licensed states, and crews that mobilize to the asset rather than waiting for it to come to them.

Northern California office

Pleasant Grove, CA3837 Howsley Rd
Pleasant Grove, CA 95668

Northern Arizona office

Flagstaff, AZFlagstaff, AZ 86001

Licensed operations

CaliforniaNevadaArizonaWashington

Additional operations in the Midwest and Southwest.

Licenses & registrations

  • CSLB #1057714 — Engineering A, C57
  • AZ ROC #337772
  • NV #0095161
  • DIR #PW-LR-1000421416
  • MBE & WBE #22000141
  • SBE #2025728

Service request

Tell us what you are protecting.

We visit the site before we estimate. Send the structure, the environment and what you already know — an engineer will come back to you, not a call center.