Company bio

Design-build corrosion engineering and cathodic protection.

Corrosion Integrity, LLC is a design-build corrosion engineering and construction company specializing in corrosion consulting, cathodic protection and asset integrity services for buried and submerged metallic infrastructure. We serve water and wastewater utilities, oil and gas operators, nuclear and power generation facilities, and municipal, state and federal agencies across the United States — from initial condition assessment through design, construction, commissioning and long-term monitoring.

Corrosion Integrity crews on site at a welded-steel potable water storage tank
Crews on site at a welded-steel potable water storage tank — cathodic protection, inspection and coating assessment.

01 · Who we are

Engineers who stay for the construction.

Headquartered in Pleasant Grove, California, with operations in Arizona and crews that mobilize nationwide, Corrosion Integrity brings more than 50 years of combined engineering experience and AMPP-certified field personnel to every project.

Our workforce of experienced operators, technicians and engineers executes work safely, efficiently and on schedule — under demanding site conditions and tight budgets — and has earned a strong reputation with utilities and public agencies throughout California, Nevada, Arizona and Washington.

Founded
2019 · Pleasant Grove, California
Model
Design-build — engineering and licensed construction under one contract
Offices
Northern California · Northern Arizona · crews mobilize nationwide
People
AMPP-certified CP and coating inspection personnel · 50+ years combined engineering experience
Licensed
CA CSLB #1057714 · AZ ROC #337772 · NV #0095161 · SBE #2025728 · MBE/WBE #22000141

02 · What we do

Measured first, then designed, then built.

Engineering & assessment

Our engineers perform corrosion failure analysis, condition assessments, corrosion and cathodic protection surveys, interference and stray-current testing, materials selection for corrosive environments, and galvanic and impressed-current CP design.

Technicians trained in non-destructive testing — magnetic flux leakage, ultrasonic testing, eddy current, guided wave and pit-depth analysis — evaluate pipelines, storage tanks and high-voltage transmission structures to establish current condition and remaining useful life.

Technician taking an ultrasonic shell thickness reading on a welded-steel water tank
UT shell survey, welded-steel water tank

Construction & installation

As a licensed contractor we self-perform anode well and groundbed installation, rectifier and remote monitoring installation, AC mitigation and grounding systems, corrosion monitoring systems, test stations, integrity digs, pipeline excavation and hydrovac support, and cathodic protection systems for storage tanks.

Because we design and build under one contract, our clients receive a single point of accountability from concept through commissioning.

Drill rig on site for a deep anode groundbed installation
Deep anode groundbed installation

03 · Core services

Six service lines, one contract.

Rectifier metering test points panel

Cathodic protection engineering & design

Galvanic and impressed-current CP design for pipelines, tanks and plant piping — soil resistivity and current-requirement testing, groundbed and rectifier sizing, solar-powered systems, and specifications to current NACE/AMPP, AWWA and API standards.

Drill rig installing a deep anode groundbed

CP construction & installation

Self-performed installation of deep and shallow groundbeds, anode wells, rectifiers and remote monitoring units, test stations, bonds and isolation, AC mitigation and grounding — with commissioning, criteria verification and as-built documentation.

Integrity dig with direct examination of buried pipe

Pipeline integrity assessment

Close-interval potential surveys, DCVG/ACVG coating surveys, interference and AC-corrosion testing, ECDA, integrity digs with direct examination, and remaining-life evaluation per NACE SP0502, TM0497 and 49 CFR Parts 192/195.

Pit-depth gauge in use during a tank floor assessment

Storage tank inspection & assessment

API 653 and STI SP001 inspections: MFL floor scanning, UT shell and floor thickness, pit-depth mapping and coating condition; interior and exterior CP evaluation and design; corrosion-rate and remaining-life determination.

Close-up of advanced corrosion on a steel surface

Condition assessment & failure analysis

Root-cause corrosion failure analysis, corrosion surveys and troubleshooting, stray-current analysis, materials selection for corrosive environments, and NDT-based condition assessment of pipelines, tanks and HV transmission structures.

Coating assessment at a welded-steel storage tank

Coating inspection & consulting

AMPP-certified coating inspection: specification development, coating selection and substrate-compatibility review including NSF/ANSI/CAN 61 systems, surface-preparation verification, holiday testing and coating failure analysis.

04 · Industries we serve

Four sectors, one failure mechanism.

Steel in contact with an electrolyte corrodes the same way whether it is a potable water reservoir or a nuclear service-water line. What changes is the standard the work is held to, and the consequence of getting it wrong.

Water & wastewater

Transmission mains, welded-steel reservoirs and elevated tanks, treatment-plant piping and clarifiers, pump stations.

Oil & gas

Gathering, transmission and distribution pipelines, terminals and tank farms, compressor and pump stations, to 49 CFR 192/195.

Nuclear

Buried piping and tank integrity support aligned with NEI 09-14 and EPRI guidance — CP evaluation, design and monitoring.

Power generation & transmission

Gas-fired and steam plants, cooling-water and fuel piping, substations and grounding, HV transmission structures.

05 · Standards and codes we work to

The editions the work is actually held to.

Cathodic protection & pipelines

CP criteria and testingNACE SP0169-2024 · TM0497-2022 · SP0207 close-interval surveys · SP0104-2020 coupons · SP0286-2007 electrical isolation

AC interferenceNACE SP0177 · SP21424-2018

Pipeline integrityNACE SP0502-2025 ECDA · TM0109-2009 DCVG/ACVG · ASME B31.8S-2025 · ASME B31G-2023 · API RP 1160 R2024 · API 570, 5th Ed. 2024 · 49 CFR Part 192 Subpart I and Part 195 Subpart H

Storage tanks

InspectionAPI Std 653, 5th Ed. incl. Addendum 4 (2025) · STI SP001, 7th Ed. (2024)

Tank CP & liningsAPI RP 651, 5th Ed. (2024) · API RP 652, 5th Ed. (2020) · NACE SP0193-2016 on-grade tank bottoms · SP0285-2021 and TM0101-2012 USTs

Water storage tanksNACE SP0196-2020 · SP0388-2018 · ANSI/AWWA D104-23 · D106-24 · D102-24 · AWWA M42 and M27 · NSF/ANSI/CAN 61

Coatings, nuclear & power

CoatingsSSPC-SP 10/NACE No. 2 (2024) · NACE SP0188-2024 holiday testing · AMPP Coating Inspector Program (CIP)

Nuclear & powerNEI 09-14, Rev. 4 underground piping and tank integrity · EPRI 3002000596 CP application and maintenance · NACE SP0169 applied to plant buried piping

Editions current as of September 2026. Where a client specification or federal incorporation-by-reference cites an earlier edition, work is performed to that edition.

06 · Offices and nationwide service

Two offices. Crews that travel.

Headquarters — Northern California

3837 Howsley Road
Pleasant Grove, CA 95668

Northern Arizona office

Flagstaff, AZ 86001

Crews mobilize to project sites nationwide.

Licenses & certifications

  • California CSLB#1057714
  • Arizona ROC#337772
  • Nevada contractor#0095161
  • SBE#2025728
  • MBE & WBE#22000141

Full certifications →

Preserving aging infrastructure — from the first soil resistivity reading to the rectifier that gets energized.

07 · Customer setup

Everything we need to invoice you.

Four blocks: who you are, who pays, where it ships, and what your risk department needs on the certificate. It is the same information your accounts payable team would ask us for anyway, gathered in one place so neither of us has to chase it halfway through a job.

About ten minutes. Anything you do not have to hand can be left for later — only the fields marked Required hold it up, and none of them is a credit check.

  • You send thisBilling and AP contacts, the ship-to site, and your COI requirements.
  • We read itA person, not the website. Usually the same day.
  • We confirmYour account is opened, the COI is issued, and purchase orders become a checkout option.

Submitting this does not open an account. Net 30 is credit, and no web form should be able to grant it. We read the application and confirm by email before anything changes at checkout.

01Your company

Who we are doing the work for.

02Bill to

Where the invoice goes, and who chases it internally.

03Ship to

Where material and crews actually turn up. Often not the billing address.

04Certificate of insurance

What your risk department needs on the certificate. Getting this right the first time saves a week at the start of the job.

05Documents

Your insurance requirements if you have them written down, and a resale or tax exemption certificate if you hold one. Everything you send here is stored privately and is never published on this site.

    06Payment terms

    Net 30 from date of invoice. Invoicing is monthly per task complete. Prices exclude freight and taxes. A 3% fee applies to credit card payments. Quoted material pricing is based on current market and availability and is subject to change if an order is not placed within 30 days.