Products

Cathodic protection components.

Anodes, reference cells, tank hardware, test stations, splice kits and off-grid power control. Sizing and specification drive price, so we quote most lines rather than list a shelf price — build a list here and we will come back with numbers.

PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size C

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size D

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size D-NZ

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

3M 82-A1 Splice Kit

Inline splice kit for unshielded, synthetic-insulated cable. UL Listed for direct burial and submerged use to 600 V and 90 °C.

PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size E

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

3M 82-A2 Splice Kit

Inline splice kit for mid-range conductors. UL Listed for direct burial and submerged use to 600 V and 90 °C.

Quoted
PlaceholderSplice kits & sealing

3M 82-A3 Splice Kit

Inline splice kit for large conductors. UL Listed for direct burial and submerged use to 600 V and 90 °C.

Quoted
PlaceholderSplice kits & sealing

3M 82-B1 Splice Kit

Tap and branch splice kit for weather-exposed and direct-burial joints, to 5 kV with a solder sleeve or compression connector.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size A

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
PlaceholderSplice kits & sealing

Scotchcast Resin 4N — Size B

Two-part epoxy insulating and encapsulating resin in a closed mixing pouch. Seals cable splices to 8 kV and generates its own cure heat.

Quoted
Off-Grid PV PolePower & control

Off-Grid PV Pole

Pole-mounted array, enclosure and storage — a complete power package for remote cathodic protection sites.

Quoted
Clevis AssemblyTank hardware

Clevis Assembly

Anode suspension hardware for tank installations — takes the mechanical load off the anode lead.

GrommetTank hardware

Grommet

Sealed cable penetration for tank roofs and hand holes.

Titanium MMO AnodeAnodes

Titanium MMO Anode

Mixed metal oxide on titanium. The workhorse impressed-current anode for potable water and wastewater storage tanks.

from$600.00
Mag Rod AnodeAnodes

Mag Rod Anode

Magnesium rod for galvanic systems — tank interiors, small structures and retrofit protection.

8" Hand Hole Cover AssemblyUncategorized

8" Hand Hole Cover Assembly

316 stainless steel access cover in the larger shell size, for multiple cable entries or where the smaller cover will not clear the terminations.

TASC / IRT Controller CardUncategorized

TASC / IRT Controller Card

Replacement controller card for TASC and IR-free rectifier units. Material price; installation is charged at the crew day rate.

$1,200.00Add to cart
PlaceholderUncategorized

9 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

17 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

20 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

32 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

48 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

60 lb Magnesium Anode

Standard-potential magnesium anode with 10 ft of No. 12 TW solid black lead, for buried pipe, casings and small structures. Anode weight drives current output and life — size it to the soil resistivity and the coated area you are protecting.

PlaceholderUncategorized

No. 10 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 8 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 6 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 4 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 2 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 1 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 1/0 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 2/0 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

No. 4/0 HMWPE Cable

High molecular weight polyethylene insulated copper, cut to length. The jacket is the reason this and not building wire: chlorine and hydroxyl generated at an anode will work through a softer insulation and take the copper with it. Halar and Kynar jackets are available to order for higher-temperature and chemically aggressive service.

PlaceholderUncategorized

5-Terminal Test Station Head

Five-terminal head for potential and current measurement points, taking the leads from the pipe, the anode and the shunt onto separate terminals so a reading is repeatable.

PlaceholderUncategorized

G5C Flush-Mount Box

Traffic-rated flush box for a station in a roadway, a shoulder or anywhere a post would be hit. The box goes in at grade and the terminal board mounts inside it.

PlaceholderUncategorized

G5CT Lid

Replacement lid for the G5C box — the part that actually gets destroyed, by a grader blade or a snow plough, long before the box does.

PlaceholderUncategorized

5" × 5" Terminal Board

Phenolic terminal board for a flush box, drilled for shunts and terminal posts so that current can be read without breaking a connection.

PlaceholderUncategorized

No. 2 Bond Jumper — 18"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 2 Bond Jumper — 24"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 2 Bond Jumper — 18" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

No. 2 Bond Jumper — 24" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

No. 4 Bond Jumper — 18"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 4 Bond Jumper — 24"

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Unsleeved, for dry and accessible joints.

PlaceholderUncategorized

No. 4 Bond Jumper — 18" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

No. 4 Bond Jumper — 24" Sleeved

Pre-cut bonding jumper for joints, valves, casings and mechanical couplings — electrical continuity across a fitting that would otherwise leave a length of main unprotected. Sleeved where it crosses the joint, so the bond cannot ground out against the fitting it spans.

PlaceholderUncategorized

CAA Cadweld Mold with Frame

Horizontal graphite mold and handle frame for cadwelding a lead to the pipe wall. One mold is good for a run of welds before the graphite erodes past a clean joint.

PlaceholderUncategorized

Royston Handy Cap

Mastic cap over the finished weld, keeping water off the bare steel and the connection. Priced singly; a box is $120.80.

PlaceholderUncategorized

Cadweld Charges

Welding charges by the package, sized to the mold and the conductor. Tell us the mold and the lead you are welding and we will price the right package.

Quoted
PlaceholderUncategorized

3M 90-B1 Splice Kit

Branch and tap splice kit for direct-burial and submerged joints — the kit for taking an anode lead onto a header cable without leaving a path to water.

PlaceholderUncategorized

Scotch 130C Linerless Rubber Tape

Self-fusing ethylene propylene rubber tape. Stretched and wrapped it fuses into one mass with no seam for water to track along, which is what makes it a splice tape rather than an insulating one.

PlaceholderUncategorized

Scotch Super 88 Vinyl Tape

Heavier vinyl tape for the same job where the splice will be pulled through soil or rock and the thinner jacket would abrade through.

PlaceholderUncategorized

C-Crimps and Split Bolts

Compression C-crimps and split-bolt connectors, sized to the conductors being joined. Tell us the two gauges and we will price the connector.

Quoted
PlaceholderUncategorized

Pin Brazing — Materials and Installation

Pin brazed lead attachment where a cadweld is not permitted — thin wall, high pressure, or an operator who will not allow an exothermic weld on a live line. Quoted with the materials and the technician together.

Quoted
0 items in quote

Your quote list

Send the list, get sized components back.

Add quantities if you know them. If you do not, leave them — the sizing questions below matter far more than the count.

    No components selected yet — add them from the catalog above.

    Send this list with a request

    How we size it

    Five answers and we can specify the system.

    Anode selection is not a catalog lookup. Current demand is set by the electrolyte and the coating, and anode life is set by the current. These are the inputs we need.

    1 — The structure

    Material, dimensions and surface area. Buried pipeline, above-grade tank, clarifier, reinforced concrete, submerged steel — each changes the geometry of the current path.

    2 — The electrolyte

    Soil resistivity in ohm-centimetres, or the water chemistry inside the tank. This single number drives ground bed design more than anything else on the list.

    3 — Coating condition

    A well-coated line needs a fraction of the current a bare one does. Age, type and known holidays let us estimate the real demand rather than the theoretical one.

    4 — Power available

    Grid power at the site, or none? No service means an off-grid PV package rather than a conventional rectifier, and that changes the whole current budget.

    5 — What is already there

    Existing anodes, rectifiers, test stations and any potential readings you have. Retrofitting into a live system is a different problem from a green-field design.

    Not sure?

    Send what you have. We would rather run a soil resistivity survey and tell you what the ground is than quote a system against assumptions.

    Ask an engineer

    Service request

    Tell us what you are protecting.

    We visit the site before we estimate. Send the structure, the environment and what you already know — an engineer will come back to you, not a call center.

    Northern California

    3837 Howsley Rd
    Pleasant Grove, CA 95668

    Northern Arizona

    Flagstaff, AZ 86001